FIRE AND GAS
DETECTION
SYSTEMS

Image is not available

Fire & Gas
Detection
Systems

Products / Marine


“ We keep moving forward, opening new doors, and doing new things,
because we’re curious & curiosity keeps leading us down new paths. ”
- Walts Disney

Responsibility … is our assurance

Slider

Fire and Gas Detection SystemsMarine/Products

 
MOWE's

FIRE AND GAS
DETECTION SYSTEMS

INTEGRATED SOLUTIONS | ENHANCED SAFETY | MARINE EXPERTISE

MOWE's experience with Fire and Gas Detection Systems in FSO/FPSO projects over the years has given customers confidence in entrusting us with more integrated projects under a complete package and single-point responsibility approach.

MOWE Fire and Gas Detection Systems
1
The Fire and Gas Detection System can be configured to meet various SIL requirements. MOWE delivers integrated Fire and Gas Detection solutions for marine, offshore and industrial applications.
A

KEY FEATURES

  • Configurable and expandable
  • Multiple Gas or Smoke detection loops
  • Single, Double or Triple PLCs with interface with FCS, PCS, ICSS
  • Hot Standby / Cold Standby
  • Client choice of detectors and field devices
  • Maintenance and testing reminder features
  • Alarm logging
B

APPLICATIONS

  • FPSO & FSO Facilities
  • Offshore Platforms
  • Oil & Gas Processing Plants
  • Tank Farms & Terminals
  • Marine Vessels & Engine Rooms

 

C

MOWE'S FIRE DETECTION SYSTEM

MOWE's Fire Detection System is designed to monitor the status of connected devices on addressable loops for fire alarms, short-circuit faults, open-circuit faults, unauthorized removal and detector or sensor fault conditions.

MOWE Fire and Gas System Configuration Diagram
D

MOWE'S GAS DETECTION SYSTEM

Flexible gas monitoring and alarm management for hazardous marine and offshore environments.

Gas detection systems monitor the protected area for combustible and toxic gases. Detector signals can be transmitted to the Fire & Gas control system for alarm monitoring, detector status indication and system fault monitoring.

Depending on the selected system configuration, gas detection signals can be provided through 4–20 mA and Modbus RS485 interfaces, with HART communication available as an optional interface where required.

Typical project configurations can support hydrocarbon gas detection from 0–100% LEL and hydrogen sulphide (H₂S) detection from 0–100 ppm.

GAS DETECTION FEATURES

  • Hydrocarbon Gas Detection: 0–100% LEL
  • H₂S Gas Detection: 0–100 ppm
  • 4–20 mA Signal Interface
  • Modbus RS485 Communication
  • HART Communication – Optional
  • 24 VDC Power Supply
  • Zone 1 Hazardous Area Application
  • 316 Stainless Steel Enclosure
  • SS316L Sensor Head
  • IP65 / IP66 Configuration

 

E

FGS PROJECT REFERENCE – FSO DULANG

MOWE Marine & Offshore delivered a Fire & Gas System package for the FSO Dulang Replacement project, covering Fire & Gas Panel and detection sensors together with project documentation and approval requirements.

FSO Dulang – Fire & Gas System

The FSO Dulang Replacement project included the provision of a Fire & Gas System comprising the Fire & Gas Panel and detection sensors for the vessel application.

The project scope included submission of approval drawings to Class BV and provision for field work associated with the existing Fire & Gas system, including onboard survey and checking, installation support and commissioning activities.

The project demonstrates MOWE's capability to coordinate Fire & Gas control equipment, detection devices, engineering documentation, inspection requirements and project-specific system integration for offshore and marine applications.

PROJECT DETAILS

  • Project: FSO Dulang Replacement
  • System: Fire & Gas System
  • Scope: Fire & Gas Panel & Detection Sensors
  • Class: BV Approval Drawings
  • Application: FSO / Offshore Marine
  • Existing System Survey & Checking
  • Commissioning Support

 

F

FIRE & GAS CONTROL PANEL

Central Monitoring, Alarm Management & System Control

The Fire & Gas Control Panel provides the central monitoring interface for connected fire and gas detection devices. The panel receives detector signals and provides alarm, status and fault information for operator monitoring and system management.

The project configuration included a dedicated gas control panel with RS485 communication, 4–20 mA input interfaces, relay contacts, siren outputs, digital zones, OLED display and event logging capabilities.

The selected configuration can be integrated with associated control and safety systems according to project requirements.

PANEL CONFIGURATION

  • 2 × RS485 Communication Interfaces
  • 8 × 4–20 mA Inputs
  • 5 × Relay Contacts
  • 24 VDC / 2 A Siren Outputs
  • IP66 Enclosure
  • OLED Display
  • Modbus RS485 Output
  • 8 Digital Zones
  • Event Logging
  • 220 VAC Supply

 

G

FIRE DETECTION DEVICES

Addressable Fire Detection for Marine & Offshore Applications

The Fire Detection System can incorporate addressable optical smoke and heat detectors together with manual call points and associated detector bases and interfaces. This configuration allows individual devices to be monitored through the fire detection loops.

For hazardous or wet-space applications, selected detection devices can be configured with intrinsically safe Ex ia protection and suitable ingress protection according to the project requirements.

FIRE DETECTION CONFIGURATION

  • Addressable Optical Smoke Detection
  • Addressable Heat Detection
  • Manual Call Points
  • Ex ia Intrinsically Safe Devices
  • Wet-Space Detection Devices
  • IP67 Manual Call Point Configuration
  • Detector Base & Adapter Arrangement
  • Addressable Fire Detection Loops

 

H

FLAME DETECTION

Rapid Flame Detection for Critical Protected Areas

Flame detectors provide rapid detection of fire by sensing the characteristic radiation generated by a flame. The Fire & Gas system can be configured to support flame detection technologies such as infrared (IR) and ultraviolet / infrared (UV-IR), depending on the selected project detector and application.

Flame detection can be integrated with the Fire & Gas control system to initiate alarm indication and support the overall emergency response philosophy defined for the project.

FLAME DETECTION TECHNOLOGIES

  • Infrared (IR) Flame Detection
  • UV-IR Flame Detection
  • Rapid Fire Detection
  • Hazardous Area Applications
  • Fire Alarm Integration
  • Project-Specific Detector Selection

 

I

GAS DETECTION TECHNICAL CONFIGURATION

Hydrocarbon & Toxic Gas Monitoring

The gas detection configuration can support both combustible hydrocarbon gas and toxic gas monitoring. The selected detectors can provide analogue and digital communication interfaces for connection to the associated Fire & Gas control system.

Detector construction can include stainless steel enclosures and SS316L sensor heads for demanding marine, offshore and hazardous-area applications.

TECHNICAL DATA

  • Hydrocarbon Range: 0–100% LEL
  • H₂S Range: 0–100 ppm
  • Output: 4–20 mA
  • Communication: Modbus RS485
  • HART: Optional
  • Power Supply: 24 VDC
  • Cable Entry: 3 × 1/2" NPT
  • Enclosure: 316 Stainless Steel
  • Sensor Head: SS316L
  • Protection: IP65 / IP66 Optional
  • Hazardous Area: Zone 1

 

J

SYSTEM COMPONENTS

MOWE's Fire and Gas Detection System can be configured with various detection, monitoring and control components to meet specific project requirements.

Flame Detector

Flame Detector

Detects fire using infrared (IR) or ultraviolet / infrared (UV-IR) technology.

Gas Detector

Gas Detector

Detects combustible hydrocarbon and toxic gases for hazardous-area applications.

Smoke Detector

Smoke Detector

Addressable optical smoke detection for early identification of fire conditions.

Heat Detector

Heat Detector

Detects abnormal temperature increase within protected areas.

Manual Call Point

Manual Call Point

Allows manual activation of a fire alarm during emergency situations.

Fire and Gas Control Panel

Fire & Gas Control Panel

Central control and monitoring system for connected Fire & Gas detection devices.

HMI Operator Workstation

HMI / Operator Workstation

User interface for real-time monitoring, alarm indication and system status management.

2

FSO DULANG FGS PROJECT

Photo FGS meeting 1 1

 

3

WHY CHOOSE MOWE?

MOWE provides integrated Fire and Gas Detection Systems designed to support reliable safety monitoring for offshore, marine and industrial applications.

  • Integrated Fire & Gas Safety Solutions
  • Customised System Configuration
  • Flexible Integration with FCS, PCS and ICSS
  • Reliable Monitoring and Alarm Systems
  • Suitable for Offshore & Marine Applications
  • Designed for Client-Specific Requirements
  • Project Engineering & Documentation
  • Inspection, Testing & Commissioning Support
MOWE Marine and Offshore Fire and Gas Solutions
Reliable Safety Solutions for Offshore and Marine Operations
4

SYSTEM INTEGRATION

MOWE Fire and Gas Detection Systems can be integrated with other safety, control and monitoring systems to provide efficient communication and reliable operation.

  • Fire & Gas Control System (FCS)
  • Process Control System (PCS)
  • Integrated Control and Safety System (ICSS)
  • Emergency Shutdown System (ESD)
  • Alarm & Monitoring Systems
  • Remote Operator Workstations
  • Engineering, Commissioning and After-Sales Support

Mowe Marine & Offshore is a member of the Association of Small and Medium Enterprises (ASME) in Singapore.

MOWE provides Fire & Gas Detection Systems (FGS), system integration, engineering support and safety monitoring solutions for marine, offshore and industrial applications . Contact us at This email address is being protected from spambots. You need JavaScript enabled to view it. for more information.